Table 114. Port Error and Status CSR n (SP n_ERR_STAT) Field Descriptions (continued)
Bit Field Value Description
1 PORT_OK The input and output ports are initialized and the port is exchanging error-free control symbols with
the attached device (read-only).
0 PORT_UNINITIA Input and output ports are not initialized. This bit and bit 1 are mutually exclusive (read-only).
LIZED
SPRU976 March 2006 Serial RapidIO (SRIO) 187