5.81 Port Link Maintenance Request CSR n (SP n_LM_REQ)
SRIO Registers
Each of the four ports is supported by a register of this type.
Figure 137. Port Link Maintenance Request CSR n (SP n_LM_REQ)
31-16
Reserved
R-0x00
LEGEND: R = Read only; - n = value after reset
15-3 2-0
Reserved COMMAND
R-0x00 RW-0x00
LEGEND: R = Read only; - n = value after reset
Table 111. Port Link Maintenance Request CSR n (SP n_LM_REQ) Field Descriptions
Bit Field Value Description
31-3 Reserved Reserved
2-0 COMMAND A write to this register generates a link-request control symbol on the corresponding port interface.
Command to be sent in the link-request control symbol. If read, this field returns the last written
value