Texas Instruments SLUU477 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 13
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
BQ24210 EVM
HPA678
GND
J1
VBUS
J2
GND
BAT
APPLICATION CIRCUIT
U1
V
Iin
I
Power supply
#1
IBAT
V
Load #1
I
TS
PG
JP1
D1
LED
CHG
D2
J4
JP4
JP5 JP7 JP6 JP2
J3
JP3
www.ti.com
Test Summary
2.5 Equipment
2.5.1 Power Supplies
Power Supply #1 (PS#1): a power supply capable of supplying 20-V at 1-A is required.
2.5.2 Loads
LOAD #1 A 20V (or above), 1A (or above) electronic load that can operate at constant current and
constant voltage mode.
Or: equivalent.
2.5.3 Meters
Four Fluke 75 multi-meters, (equivalent or better)
Or: Two equivalent voltage meters and two equivalent current meters.
The current meters must be capable of measuring 1A+ current.
2.6 Equipment Setup
1. Set the power supply #1 (PS#1) for 6.5V ± 200mVDC, 1A ± 0.1A current limit and then turn off supply.
2. Connect the output of PS#1 in series with a current meter (multi-meter) to J1 (VBUS, GND).
3. Connect a voltage meter across J1 (VBUS, GND).
4. Connect Load #1 in series with a current meter to J2 (VBAT, GND). Turn off Load #1.
5. Connect a voltage meter across J2 (VBAT, GND).
6. Check all jumper shunts. JP1: OFF; JP2: OFF; JP3: OFF; JP4: OFF; JP5: connect 1-2 (External TS);
JP6: connect 2-3 (VBUS); JP7: connect 1-2 (charger OFF).
Figure 1. Original Test Setup for HPA678 (bq24210 EVM)
5
SLUU477December 2010 800mA, Single-Input, Single Cell Li-Ion Battery Solar Charger with Power Path
Submit Documentation Feedback
© 2010, Texas Instruments Incorporated
Page view 4
1 2 3 4 5 6 7 8 9 10 11 12 13

Comments to this Manuals

No comments